Home Other EMS rarely suspects PE, but detection speeds CT
Other
EMS rarely suspects PE, but detection speeds CT
Prehospital Detection of Acute Pulmonary Embolism and Its Association with Clinical Outcomes: A Retrospective Cohort Study
Journal of Clinical Medicine · Added 3 November 2026
A German retrospective cohort of 171 EMS-transported patients with confirmed pulmonary embolism found prehospital crews correctly suspected PE in only 5.3% of cases, but correct detection was associated with time to CT pulmonary angiography halving (median 2.1 vs 4.0 hours).
- Study type
- Cohort
- Design
- Retrospective single-centre cohort, EMS protocols 2019-2024
- Participants
- 171 EMS-transported patients with in-hospital confirmed PE, Bochum, Germany
- Main finding
- PE correctly suspected prehospital in 9/171 (5.3%, 95% CI 2.8-9.7%); time to CTPA 2.1 vs 4.0 hours with detection (p<0.001); detection only in physician-staffed encounters (10.8% vs 0%, p=0.003); 22.5% diagnosed only after 24 hours
- Caveat
- Single centre, retrospective, detection defined by EMS documentation, physician-staffed system, exploratory analyses
- Bottom line
- Hypothesis-generating
Why it matters in Australia (Medium relevance). Done in a physician-staffed German system, so the detection rate isn't directly comparable — but the core message, that PE is rarely suspected before hospital and detection speeds imaging, applies in any paramedic-led system.
Learning goal
Recognise prehospital presentations of pulmonary embolism to speed diagnosis and improve patient outcomes.
More
- Topic: Other
- Daily scan: 3 November 2026
Related papers on Other
-
Counted drip rates vary widely between paramedics
In a controlled US laboratory simulation, 55 paramedics setting nine drip rates on a standardised gravity set produced overall flow errors from -45.3% to +5.8%, with imprecision driven mainly by human counting and whole-number target rates more accurate than fractional ones.
-
AI in prehospital care: cautious optimism, thin validation
A critical narrative review of AI in emergency and prehospital care found the most credible near-term uses are bounded decision support — triage, risk stratification, stroke pathways, forecasting, documentation — while retrospective designs, thin external validation and workflow gaps keep real-world benefit unproven.
-
Simulated EMS care held up at altitude
In a Swiss randomised crossover simulation study, 20 non-acclimatised EMS physicians showed no significant drop in overall performance at 3,450 m altitude (composite 82% at baseline vs 74% acute exposure, p=0.082).
-
Few heat-stroke cooling devices suit the prehospital setting
A US systematic review of 18 commercial heat-stroke cooling devices found only three reached the ideal prehospital cooling rate (at least 0.155°C/min) and just five met single-person portability, with most relying on water, power or disposables.