Home Airway & ventilation VAPOX preoxygenation in ED intubation
Airway & ventilation
VAPOX preoxygenation in ED intubation
Efficacy and Safety of Ventilator Assisted Preoxygenation for Intubation in Two Australian Emergency Departments: A Retrospective Cohort Study
Emergency Medicine Australasia · Added 22 September 2026
Australian retrospective cohort of 116 patients intubated with ventilator-assisted preoxygenation (VAPOX) in two EDs — 78% achieved first-pass success without hypoxaemia, but half had at least one complication and 36% became hypotensive after intubation
- Study type
- Cohort
- Design
- Retrospective cohort study in two Australian EDs
- Participants
- 116 adults intubated with VAPOX
- Main finding
- First-pass success without hypoxaemia in 78% (95% CI 69–84%); overall first-pass success 91%; hypoxaemia 17%; post-intubation hypotension 36%; no aspiration; respiratory failure reduced success (OR 0.14, 95% CI 0.04–0.52)
- Caveat
- Retrospective design with no comparator group
- Bottom line
- Context only
Why it matters in Australia (High relevance). transferability — Australian data directly relevant to preoxygenation before intubation (CMG 3B, ICP-only) — VAPOX is an ED ventilator setup, but the oxygenation physiology and complication profile inform how ICPs prep a physiologically difficult airway
Learning goal
Update my approach to preoxygenation before intubation by weighing ventilator-assisted techniques against standard bag-mask methods.
More
- Topic: Airway & ventilation
- Daily scan: 22 September 2026
Related papers on Airway & ventilation
-
NRB + nasal cannula inferior to flush-rate preoxygenation
Healthy-volunteer crossover study — NRB plus nasal cannula at 15–25 L/min each produced expired oxygen of 68–75% versus 85% for flush-rate NRB, so the portable-cylinder workaround is inferior when supply allows flush rate.
-
Feedback improves neonatal face mask ventilation
Prospective simulation study in neonatology fellows testing low-dose, high-frequency face mask ventilation practice with real-time respiratory function monitor feedback across T-piece, self-inflating and flow-inflating bags — feedback lifted tidal volumes in target range from 62.3% to 80.3% and cut mask leak on every device, while extra sessions without feedback added little.
-
SGA vs intubation in OHCA: ROSC lower with SGA
Systematic review and meta-analysis comparing supraglottic airway devices with endotracheal intubation in out-of-hospital cardiac arrest. Abstract not yet available (ahead-of-print).
-
Ventilation feedback devices inaccurate during CPR
Simulation cross-over study of two commercial ventilation feedback devices used during continuous compressions with asynchronous ventilations — both were clinically inaccurate, one displaying 111 breaths/min when the true rate was 12 and underestimating tidal volume by up to 440 mL in reversed airflow.