Low-dose, high-frequency simulation with respiratory function monitor feedback enhances face mask ventilation across neonatal resuscitation devices: A prospective study in neonatology fellows
Resuscitation Plus · Added 26 September 2026

Prospective simulation study in neonatology fellows testing low-dose, high-frequency face mask ventilation practice with real-time respiratory function monitor feedback across T-piece, self-inflating and flow-inflating bags — feedback lifted tidal volumes in target range from 62.3% to 80.3% and cut mask leak on every device, while extra sessions without feedback added little.

Study type
Simulation
Design
Prospective single-centre simulation study with repeated measures
Participants
Neonatology fellows (number not reported) performing simulated ventilation on three devices
Main finding
Tidal volume within target range 80.3% vs 62.3% with respiratory function monitor feedback (p<0.0001); mask leak lower with feedback on all devices; extra sessions without feedback did not improve TV or mask leak
Caveat
Simulated setting with in-hospital clinicians, not paramedics; single centre
Bottom line
Context only

Why it matters in Australia (Medium relevance). respiratory function monitors aren't carried on ambulances, but the training lesson (real-time feedback beats repetition alone for BMV) transfers to CMG 5B neonate resus drills

Learning goal

Strengthen my mask ventilation technique during neonatal resuscitation by recognising and correcting excessive leak and inadequate tidal volumes.