Home Paediatrics Infant carry slings rarely linked to OHCA
Paediatrics
Infant carry slings rarely linked to OHCA
Infant carry sling-associated out-of-hospital cardiac arrest and other circumstances surrounding such events in children under two years: A five-year regional registry analysis
Resuscitation Plus · 2026-10 · Added 23 October 2026
A five-year English regional registry review of 162 cardiac arrests in children under two found only two linked to infant carry slings, while co-sleeping featured in a third of cases.
- Study type
- Registry
- Design
- Retrospective registry service evaluation
- Participants
- 162 children under two who received a resuscitation attempt
- Main finding
- Only 2 of 162 OHCA were carry sling-associated (1.8% of the 114 infant cases); co-sleeping accounted for 33.3% and children found unresponsive 26.3%
- Caveat
- Small single-region sample relying on free-text narrative review — two events over five years can't exclude a rare risk
- Bottom line
- Hypothesis-generating
Why it matters in Australia (High relevance). Sleep-related infant arrests — co-sleeping, found unresponsive in a cot, bed, sofa or pushchair — are the same scenes Australian crews attend, and nothing about a single-region English ambulance registry makes the numbers system-specific.
Learning goal
Recognise how carry slings and co-sleeping environments contribute to sudden deterioration in infants under two.
More
- Topic: Paediatrics
- Daily scan: 23 October 2026
- Podcast: Paramedic Papers Daily, 23 October 2026
Related papers on Paediatrics
-
Neonatal calls rare on South African ambulances
A two-year review of 9,825 neonatal activations in the Western Cape public EMS found neonates were just 0.7% of workload with rare high-risk interventions (prehospital intubation 0.4%), and non-specialist crews attended two-thirds of high-acuity cases despite limited neonatal scope of practice.
-
Paediatric deterioration in the field poorly defined
A scoping review of 28 studies found no standardised definition of paediatric out-of-hospital clinical deterioration and almost no research on how crews actually recognise it.
-
Paediatric care coordinators linked to fewer EMS errors
A US cross-sectional study of 2,219 paediatric EMS encounters found agencies with a paediatric emergency care coordinator delivered more procedures and medications, with fewer and less severe adverse safety events.
-
Feedback device lifts paediatric ventilation quality
Randomised crossover simulation study with 123 EMS clinicians testing a ventilation feedback device on a paediatric manikin — guideline-adherent tidal volumes jumped from 16.2% to 87% of breaths with feedback, and rate adherence from 65% to 88.6%.