Cardiopulmonary resuscitation quality during the transition in care from paramedic services to emergency department teams
Prehospital Emergency Care · Added 15 September 2026

Observational study of 35 OHCA transfers tracking CPR quality across the paramedic-to-ED handover — chest compression fraction (89–92%) and rate stayed guideline-compliant in every interval with no deterioration at transition, though compression depth was significantly deeper during paramedic intervals.

Study type
Cohort
Design
Retrospective observational study of defibrillator CPR metrics
Participants
35 adults with non-traumatic OHCA transported to a tertiary academic ED
Main finding
Chest compression fraction (89–92%) and rate (109.9–117.5/min) were guideline compliant in all four intervals with no significant differences; compression depth was deeper in ED intervals (significantly higher than paramedic 5.8–5.9 cm).
Caveat
Small sample from a single tertiary ED; retrospective design.
Bottom line
Context only

Why it matters in Australia (High relevance). transferability — direct evidence on paramedic-delivered CPR at handover, mapping to CMG 4 and everyday AP practice

Learning goal

Update my approach to maintaining compression quality during handover of cardiac arrest care at the emergency department.