Home Cardiac arrest New Penang OHCA registry shows low survival
Cardiac arrest
New Penang OHCA registry shows low survival
Establishment of an out-of-hospital cardiac arrest registry in Penang, Malaysia
Resuscitation Plus · Added 16 August 2026
Descriptive analysis of 5,087 OHCA cases showed 16.3% received EMS resuscitation attempts, with only 1.3% 30-day survival despite bystander CPR in 43.5% of cases, and AED deployment in only 7.1%.
- Study type
- Registry
- Design
- Descriptive analysis of first-year registry data (Utstein template)
- Participants
- 5,087 OHCA cases
- Main finding
- 16.3% had an EMS resuscitation attempt; bystander CPR in 43.5%, AED applied in 7.1%, ROSC in 10.3%, 30-day survival 1.3%; median ambulance response time 21 min
- Caveat
- Descriptive single-region data from a newly established registry with very different EMS system to Australia
- Bottom line
- Context only
Why it matters in Australia (Medium relevance). Valuable registry data but from Malaysia with different EMS system and longer response times (median 21 min), though low AED deployment findings are broadly relevant.
Learning goal
Recognise the system factors that influence bystander CPR and AED use in out-of-hospital cardiac arrest.
More
- Topic: Cardiac arrest
- Daily scan: 16 August 2026
Related papers on Cardiac arrest
-
Prolonged fasting raises defibrillation needs in pigs
Porcine model of ventricular fibrillation cardiac arrest found that prolonged fasting-induced lower pre-arrest glycemia was associated with increased defibrillation requirements (median 2 vs 1 shock) and longer CPR duration, despite similar sustained ROSC rates.
-
Loss of pulsatility predicts death after ECPR
Retrospective cohort of 221 ECPR patients found loss of pulsatility (zero pulse pressure) occurred in 49% of cases and was associated with significantly higher in-hospital mortality (74% vs 48%), with each additional hour of non-pulsatility increasing mortality risk by 17%
-
CPR leader app no help in simulation
Randomized simulation trial of 40 teams testing the 'CPR Leader' app during in-hospital cardiac arrest found no meaningful improvement in team performance, non-technical skills, or ALS algorithm adherence compared to control
-
No risky oxygen build-up at defibrillation site in CPR
Mannequin study testing whether removing oxygen-delivery devices reduces ambient oxygen concentration at defibrillation sites — it found no clinically relevant oxygen accumulation, and removing devices made no difference to oxygen levels.